Constructions
Conductor: Round, stranded and compacted aluminum conductor
Insulation: HDPE, XLPE, PVC
Applications
Aerial Bunch Cables are basically a compromise construction between Power cables and Overhead conductors. It is preferred to use of ABC cables instead of uninsulated conductors at low voltage networks. ABC cables are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like villages. Bundles can include one or two additional conductors for public lighting and control pair.
Standards
GB12527-91,IEC502, BS7870-5
Other standards such as BS,DIN and ICEA upon request
Specifications
Cross Section of Conductor
Min.Nos. of Wires for Conductor
Insulation Thickness
Average Max. O.D.per Single-core
Max.Conductor Resistance at 20℃
Min Insulated Resistance at Rated Working Temperature
Cable Tensile Breaking Force
70℃
90℃
2x10
6
1.00
6.5x13.0
3.08
0.0067
0.67
1650
2x16
6
1.20
8.0x16.0
1.91
0.0065
0.65
2512
2x25
6
1.20
9.4x18.8
1.2
0.0054
0.54
3762
2x35
6
1.40
11.0x22.0
0.868
0.0054
0.54
5177
2x50
6
1.40
12.3x24.6
0.641
0.0064
0.46
7011
2x70
12
1.40
14.1x28.2
0.443
0.004
0.4
10354
2x95
15
1.60
16.5x33.0
0.32
0.0039
0.39
13727
2x120
15
1.60
18.1x36.2
0.252
0.0035
0.35
17339
2x150
15
1.80
20.2x40.4
0.206
0.0035
0.35
21033
2x185
30
2.00
22.5x45.0
0.164
0.0035
0.35
26732
2x240
30
2.20
25.6x51.2
0.125
0.0034
0.34
34679
4x10
6
1.00
6.5x26.0
3.08
0.0067
0.67
1650
4x16
6
1.20
8.0x32.0
1.91
0.0065
0.65
2512
4x25
6
1.20
9.4x37.6
1.2
0.0054
0.54
3762
4x35
6
1.40
11.0x44.0
0.868
0.0054
0.54
5177
4x50
6
1.40
12.3x49.2
0.641
0.0046
0.46
7011
4x70
12
1.40
14.1x56.4
0.443
0.004
0.4
10354
4x95
15
1.60
16.5x66.0
0.32
0.0039
0.39
13727
4x120
15
1.60
18.1x72.4
0.252
0.0035
0.35
17339
4x150
15
1.80
20.2x80.8
0.206
0.0035
0.35
21033
4x185
30
2.00
22.5x90.0
0.164
0.0035
0.35
26732
4x240
30
2.20
25.6x102.4
0.125
0.0034
0.34
34679
(mm2)
(mm)
(mm)
(mm)
(Ω/km)
(MΩ.km)